MTL5516C - Switch/Proximity detector interface Two channel, with line-fault detection
The MTL5516C contains two changeover relays, which enable two safe-area loads to be controlled by switches or proximity detectors located in a hazardous-area. When selected, the line-fault detect (LFD) facility detects open or short circuit conditions in the field wiring and also indicates this on the top of the module. Line-Fault Detect and Phase Reversal for the channel are selected by DIL switches on the side of the module and output is provided by the changeover relay contacts
Terminal
|
Function
|
1
|
Input -ve (Ch 1)
|
2
|
Input +ve (Ch 1)
|
4
|
Input -ve (Ch 2)
|
5
|
Input +ve (Ch 2)
|
7
|
Normally-closed contact (Ch 2)
|
8
|
Common (Ch 2)
|
9
|
Normally-open contact (Ch 2)
|
10
|
Normally-closed contact (Ch 1)
|
11
|
Common (Ch 1)
|
12
|
Normally-open contact (Ch 1)
|
13
|
Supply -ve
|
14
|
Supply +ve
|
|